Campbell Time Series

The Campbell data logger controls MOBYs functional timing. It turns on the Falcon controller computer which will do a task depending upon the time it is powered up. The Campbell is also programed to power down the buoy at programmable times to make sure the system is shutdown at least once per day to return the system to a known state. The Falcon always boots from a cold state at power up. The Campbell operates based on a proprietary CRBasic programing language. Campbell analog Inputs measure Battery voltage, Campbell unit panel temperature, Case Air Temperature, Case Humidity, state of the Falcon Main Power Relay and state of the Charge Relay. Campbell has override control of the Main Power Relay and the Charge Relay. Campbell modem power is also controlled by the Campbell. The Campbell data table contains a record of the above parameters as well as important program flow flags. The voltage monitored by the Campbell is actually the voltage of the Campbell backup battery which is diode isolated from the Campbell and the Upper Battery. Due to the isolated battery supplies, this voltage is not much use in quantitatively monitoring the health of the Upper Battery. The Campbell backup battery only powers the Campbell when the Upper Battery falls below about 11.5 volts. The Campbell will operate down to a voltage of 10.5 volts at which point it will only try to switch the Charge Really to the Upper Battery to try and gain power for the controller rather than any lower batteries.

MainRlyState, 0=False=Off -1=True=On
ChargeRlyState, 0=False=Down -1=True=Up
MainRlyState is the feedback from the power relay controlling the Falcon
ChargeRlyState is the feedback from the charge relay that switches the PV power to the Upper or Lower batteries
kohms is a flooding sensor, it will go below 10K if the housing contains free water
Campbell battery = BattV
Solar panel (PhotoVoltaic cell) voltage = PVVolts


Reading for the last day of the file: 25-Jan-2018 17:44:00 to 24-Jan-2018 17:44:00 (1 day)
Measurment Mean Min Max %std
CamBattV 13.0444 12.31 13.88 2.69
PTemp_C 25.705 24.33 29.3 5.33
AirTC 25.4919 24.1 29.62 5.86
RH 32.2281 31.2 35.66 3.55
kohms 13.1001 11.83 13.95 2.13
Measurment Minutes Down Minutes Up
ChargeRlyState 5.8833 18.1333
Measurment Minutes Off Minutes On
MainRlyState 20.5667 3.45

Means for the last 10 days for each day in the file (times and days from GMT time)
Day BattV PTemp_C AirTC RH kohms
15-Jan-2018 12.9678 26.0146 25.7797 32.1791 12.9423
16-Jan-2018 12.8788 26.0198 25.8038 32.0773 12.9627
17-Jan-2018 13.1107 25.6405 25.3984 31.7154 13.0077
18-Jan-2018 12.7152 25.9983 25.7826 32.1445 12.9911
19-Jan-2018 12.666 26.1022 25.9046 32.2412 12.9878
20-Jan-2018 12.6572 26.1036 25.9041 32.4394 13.0016
21-Jan-2018 13.0291 25.9032 25.7131 32.1992 13.0364
22-Jan-2018 12.6718 25.8224 25.5293 32.4558 13.0429
23-Jan-2018 12.9119 26.0563 25.881 32.4735 13.0378
24-Jan-2018 12.9538 26.0932 25.9434 32.4128 13.0583
25-Jan-2018 13.1048 25.3842 25.0859 31.7803 13.1375

Campbell Start and Stop Times for turning on (last 20 cycles) - MainRlyState = -1
On/Off Start Time Stop Time Delta Time (hours)
On 23-Jan-2018 23:45:00 24-Jan-2018 00:52:00 1.12
Off 24-Jan-2018 00:53:00 24-Jan-2018 02:59:00 2.10
On 24-Jan-2018 03:00:00 24-Jan-2018 03:16:00 0.27
Off 24-Jan-2018 03:17:00 24-Jan-2018 03:59:00 0.70
On 24-Jan-2018 04:00:00 24-Jan-2018 04:16:00 0.27
Off 24-Jan-2018 04:17:00 24-Jan-2018 16:59:00 12.70
On 24-Jan-2018 17:00:00 24-Jan-2018 17:16:00 0.27
Off 24-Jan-2018 17:17:00 24-Jan-2018 17:59:00 0.70
On 24-Jan-2018 18:00:00 24-Jan-2018 18:16:00 0.27
Off 24-Jan-2018 18:17:00 24-Jan-2018 20:37:00 2.33
On 24-Jan-2018 20:38:00 24-Jan-2018 21:44:00 1.10
Off 24-Jan-2018 21:45:00 24-Jan-2018 22:07:00 0.37
On 24-Jan-2018 22:08:00 24-Jan-2018 23:14:00 1.10
Off 24-Jan-2018 23:15:00 24-Jan-2018 23:44:00 0.48
On 24-Jan-2018 23:45:00 24-Jan-2018 23:49:00 0.07
Off 24-Jan-2018 23:50:00 25-Jan-2018 02:59:00 3.15
On 25-Jan-2018 03:00:00 25-Jan-2018 03:16:00 0.27
Off 25-Jan-2018 03:17:00 25-Jan-2018 03:59:00 0.70
On 25-Jan-2018 04:00:00 25-Jan-2018 04:16:00 0.27
Off 25-Jan-2018 04:17:00 25-Jan-2018 16:59:00 12.70
On 25-Jan-2018 17:00:00 25-Jan-2018 17:16:00 0.27

Start and Stop Times for when Falcon switches the Charge Relay (last 20 cycles) - ChargeRlyState = -1
Up/Down Start Time Stop Time Delta Time (hours)
Up 23-Jan-2018 23:47:00 23-Jan-2018 23:51:00 0.07
Down 23-Jan-2018 23:52:00 24-Jan-2018 00:45:00 0.88
Up 24-Jan-2018 00:46:00 24-Jan-2018 03:08:00 2.37
Down 24-Jan-2018 03:09:00 24-Jan-2018 04:01:00 0.87
Up 24-Jan-2018 04:02:00 24-Jan-2018 04:06:00 0.07
Down 24-Jan-2018 04:07:00 24-Jan-2018 04:07:00 0.00
Up 24-Jan-2018 04:08:00 24-Jan-2018 17:06:00 12.97
Down 24-Jan-2018 17:07:00 24-Jan-2018 17:07:00 0.00
Up 24-Jan-2018 17:08:00 24-Jan-2018 18:06:00 0.97
Down 24-Jan-2018 18:07:00 24-Jan-2018 20:39:00 2.53
Up 24-Jan-2018 20:40:00 24-Jan-2018 20:43:00 0.05
Down 24-Jan-2018 20:44:00 24-Jan-2018 21:38:00 0.90
Up 24-Jan-2018 21:39:00 24-Jan-2018 22:13:00 0.57
Down 24-Jan-2018 22:14:00 24-Jan-2018 23:07:00 0.88
Up 24-Jan-2018 23:08:00 24-Jan-2018 23:09:00 0.02
Down 24-Jan-2018 23:10:00 24-Jan-2018 23:46:00 0.60
Up 24-Jan-2018 23:47:00 25-Jan-2018 03:08:00 3.35
Down 25-Jan-2018 03:09:00 25-Jan-2018 04:01:00 0.87
Up 25-Jan-2018 04:02:00 25-Jan-2018 04:06:00 0.07
Down 25-Jan-2018 04:07:00 25-Jan-2018 04:07:00 0.00
Up 25-Jan-2018 04:08:00 25-Jan-2018 17:44:00 13.60