Campbell Time Series

The Campbell data logger controls MOBYs functional timing. It turns on the Falcon controller computer which will do a task depending upon the time it is powered up. The Campbell is also programed to power down the buoy at programmable times to make sure the system is shutdown at least once per day to return the system to a known state. The Falcon always boots from a cold state at power up. The Campbell operates based on a proprietary CRBasic programing language. Campbell analog Inputs measure Battery voltage, Campbell unit panel temperature, Case Air Temperature, Case Humidity, state of the Falcon Main Power Relay and state of the Charge Relay. Campbell has override control of the Main Power Relay and the Charge Relay. Campbell modem power is also controlled by the Campbell. The Campbell data table contains a record of the above parameters as well as important program flow flags. The voltage monitored by the Campbell is actually the voltage of the Campbell backup battery which is diode isolated from the Campbell and the Upper Battery. Due to the isolated battery supplies, this voltage is not much use in quantitatively monitoring the health of the Upper Battery. The Campbell backup battery only powers the Campbell when the Upper Battery falls below about 11.5 volts. The Campbell will operate down to a voltage of 10.5 volts at which point it will only try to switch the Charge Really to the Upper Battery to try and gain power for the controller rather than any lower batteries.

MainRlyState, 0=False=Off -1=True=On
ChargeRlyState, 0=False=Down -1=True=Up
MainRlyState is the feedback from the power relay controlling the Falcon
ChargeRlyState is the feedback from the charge relay that switches the PV power to the Upper or Lower batteries
kohms is a flooding sensor, it will go below 10K if the housing contains free water
Campbell battery = BattV
Solar panel (PhotoVoltaic cell) voltage = PVVolts


Reading for the last day of the file: 14-Aug-2017 22:04:00 to 13-Aug-2017 22:04:00 (1 day)
Measurment Mean Min Max %std
CamBattV 12.9373 12.49 14.2 2.54
PTemp_C 27.7773 25.98 31.5 6.18
AirTC 27.1709 24.86 31.87 7.69
RH 28.9287 28.3 30.29 1.77
kohms 11.6029 10.67 12.41 2.02
Measurment Minutes Down Minutes Up
ChargeRlyState 8.5833 15.4333
Measurment Minutes Off Minutes On
MainRlyState 17.9 6.1167

Means for the last 10 days for each day in the file (times and days from GMT time)
Day BattV PTemp_C AirTC RH kohms
04-Aug-2017 13.1745 27.7212 27.3524 27.6871 11.0985
05-Aug-2017 13.2214 29.2156 28.7848 28.1797 11.0681
06-Aug-2017 13.4893 27.8559 27.0653 28.2278 11.2965
07-Aug-2017 13.2514 27.3175 26.5021 28.2932 11.4289
08-Aug-2017 13.1241 27.5982 26.8631 28.3501 11.4496
09-Aug-2017 12.8951 27.7557 27.0898 28.4936 11.466
10-Aug-2017 12.9003 28.0502 27.319 28.7597 11.4623
11-Aug-2017 12.915 27.9182 27.1237 28.7298 11.5276
12-Aug-2017 12.8412 27.7864 27.0277 28.708 11.5737
13-Aug-2017 12.926 27.6169 26.8693 28.8844 11.6059
14-Aug-2017 12.9182 27.5951 26.924 28.8895 11.6215

Campbell Start and Stop Times for turning on (last 20 cycles) - MainRlyState = -1
On/Off Start Time Stop Time Delta Time (hours)
On 13-Aug-2017 04:00:00 13-Aug-2017 04:20:00 0.33
Off 13-Aug-2017 04:21:00 13-Aug-2017 16:59:00 12.63
On 13-Aug-2017 17:00:00 13-Aug-2017 17:20:00 0.33
Off 13-Aug-2017 17:21:00 13-Aug-2017 17:59:00 0.63
On 13-Aug-2017 18:00:00 13-Aug-2017 18:20:00 0.33
Off 13-Aug-2017 18:21:00 13-Aug-2017 20:37:00 2.27
On 13-Aug-2017 20:38:00 13-Aug-2017 22:02:00 1.40
Off 13-Aug-2017 22:03:00 13-Aug-2017 22:07:00 0.07
On 13-Aug-2017 22:08:00 13-Aug-2017 23:30:00 1.37
Off 13-Aug-2017 23:31:00 13-Aug-2017 23:44:00 0.22
On 13-Aug-2017 23:45:00 14-Aug-2017 01:39:00 1.90
Off 14-Aug-2017 01:40:00 14-Aug-2017 02:59:00 1.32
On 14-Aug-2017 03:00:00 14-Aug-2017 03:20:00 0.33
Off 14-Aug-2017 03:21:00 14-Aug-2017 03:59:00 0.63
On 14-Aug-2017 04:00:00 14-Aug-2017 04:20:00 0.33
Off 14-Aug-2017 04:21:00 14-Aug-2017 16:59:00 12.63
On 14-Aug-2017 17:00:00 14-Aug-2017 17:20:00 0.33
Off 14-Aug-2017 17:21:00 14-Aug-2017 17:59:00 0.63
On 14-Aug-2017 18:00:00 14-Aug-2017 18:20:00 0.33
Off 14-Aug-2017 18:21:00 14-Aug-2017 20:37:00 2.27
On 14-Aug-2017 20:38:00 14-Aug-2017 22:02:00 1.40

Start and Stop Times for when Falcon switches the Charge Relay (last 20 cycles) - ChargeRlyState = -1
Up/Down Start Time Stop Time Delta Time (hours)
Up 13-Aug-2017 03:02:00 13-Aug-2017 03:09:00 0.12
Down 13-Aug-2017 03:10:00 13-Aug-2017 04:06:00 0.93
Up 13-Aug-2017 04:07:00 13-Aug-2017 17:08:00 13.02
Down 13-Aug-2017 17:09:00 13-Aug-2017 18:01:00 0.87
Up 13-Aug-2017 18:02:00 13-Aug-2017 18:08:00 0.10
Down 13-Aug-2017 18:09:00 13-Aug-2017 20:39:00 2.50
Up 13-Aug-2017 20:40:00 13-Aug-2017 22:33:00 1.88
Down 13-Aug-2017 22:34:00 13-Aug-2017 23:25:00 0.85
Up 13-Aug-2017 23:26:00 13-Aug-2017 23:28:00 0.03
Down 13-Aug-2017 23:29:00 13-Aug-2017 23:46:00 0.28
Up 13-Aug-2017 23:47:00 13-Aug-2017 23:51:00 0.07
Down 13-Aug-2017 23:52:00 14-Aug-2017 00:44:00 0.87
Up 14-Aug-2017 00:45:00 14-Aug-2017 00:47:00 0.03
Down 14-Aug-2017 00:48:00 14-Aug-2017 03:01:00 2.22
Up 14-Aug-2017 03:02:00 14-Aug-2017 03:07:00 0.08
Down 14-Aug-2017 03:08:00 14-Aug-2017 04:01:00 0.88
Up 14-Aug-2017 04:02:00 14-Aug-2017 17:08:00 13.10
Down 14-Aug-2017 17:09:00 14-Aug-2017 18:01:00 0.87
Up 14-Aug-2017 18:02:00 14-Aug-2017 18:08:00 0.10
Down 14-Aug-2017 18:09:00 14-Aug-2017 20:39:00 2.50
Up 14-Aug-2017 20:40:00 14-Aug-2017 22:04:00 1.40


Stephanie Flora - Moss Landing Marine Laboratories